人妻在线欧美视频|中文字幕在线人成视频欧美|欧美一区亚洲国产粉|亚洲全部无码中文字幕

<b id="37kmu"></b>

<b id="37kmu"></b>

<b id="37kmu"></b>

產(chǎn)品中心

一步法人生長激素(GH)酶聯(lián)免疫吸附檢測試劑盒
ELK006ES
規(guī)格: 價格:
48T ¥2240.00
96T ¥3200.00

Overview

Product name: EasyStep Human GH(Growth Hormone) ELISA Kit
Reactivity: Human
Alternative Names: GH1; GH-N; GHN; hGH-N; Somatotropin; Hygetropin; Jintropin; Kigtropin; Pituitary Growth Hormone; Growth Hormone, Normal
Assay Type: Sandwich
Sensitivity: 0.2 pg/mL
Standard: 800 pg/mL
Detection Range: 12.5-800 pg/mL
Sample Type: Serum, plasma
Assay Length: 1.5h
Research Area: Endocrinology;Neuro science;Hormone metabolism;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human GH, and the Human GH standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Human GH. After TMB substrate solution is added, only those wells that contain Human GH and HRP-conjugated antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human GH in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
800.00 2.443 2.393
400.00 1.779 1.729
200.00 1.075 1.024
100.00 0.561 0.511
50.00 0.322 0.271
25.00 0.195 0.145
12.50 0.121 0.070
0.00 0.050 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant GH and the recovery rates were calculated by comparing the measured value to the expected amount of GH in samples.
Matrix Recovery range Average
serum(n=5) 96-109% 104%
EDTA plasma(n=5) 98-108% 101%
Heparin plasma(n=5) 90-102% 96%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of GH and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 89-101% 99-108% 93-101% 93-103%
EDTA plasma(n=5) 91-102% 94-101% 93-104% 96-109%
Heparin plasma(n=5) 83-97% 90-107% 88-96% 94-103%

產(chǎn)品成分表

關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉