人妻在线欧美视频|中文字幕在线人成视频欧美|欧美一区亚洲国产粉|亚洲全部无码中文字幕

<b id="37kmu"></b>

<b id="37kmu"></b>

<b id="37kmu"></b>

產(chǎn)品中心

人γ-氨基丁酸(gABA)酶聯(lián)免疫吸附檢測試劑盒
ELK0753
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻(xiàn)

Product name: Human gABA(Gamma-Aminobutyric Acid) ELISA Kit
Reactivity: Human
Alternative Names: 4-Aminobutyric Acid
Assay Type: Competitive Inhibition
Sensitivity: 14.6 pg/mL
Standard: 2000 pg/mL
Detection Range: 31.25-2000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 2.5h
Research Area: Signal transduction;Cardiovascular biology;Neuro science;Bone metabolism;
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Human gABA protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human gABA. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human gABA in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
2000.00 0.174
1000.00 0.477
500.00 0.673
250.00 0.949
125.00 1.142
62.50 1.545
31.25 1.835
0.00 2.115

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant gABA and the recovery rates were calculated by comparing the measured value to the expected amount of gABA in samples.
Matrix Recovery range Average
serum(n=5) 83-95% 89%
EDTA plasma(n=5) 92-107% 99%
Heparin plasma(n=5) 85-99% 92%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of gABA and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-98% 85-93% 87-98% 89-103%
EDTA plasma(n=5) 87-98% 92-105% 95-104% 97-105%
Heparin plasma(n=5) 82-95% 98-105% 82-93% 95-102%
關(guān)閉